info@publicacionesrep.com.mx

Analysis of partial load loss of the PCS and internal storage battery loss in residential PV power generation and storage battery systems

Abstract

This study aims to quantify the amount of loss due to partial load of power conditioning system (PCS) and internal loss of storage battery in residential photovoltaic (PV) power generation and storage battery system by using home energy management system (HEMS) data. After identifying the configuration of the PV power generation and storage battery system, HEMS data on PV power generation, household demand, storage battery charging, storage battery discharging, purchased power and sold power were extracted and analyzed according to the research purpose. As a result, the loss due to partial load of the PCS and the average internal loss of the storage battery were quantified. In addition, it was confirmed that a more realistic system simulation could be performed by considering the impact of the partial load of the PCS and the average internal loss of the storage battery.

Leer más Electronics and Communications in Japan, EarlyView. 

Analysis of partial load loss of the PCS and internal storage battery loss in residential PV power generation and storage battery systems